Ozone Generator, PA2500

PA 2500 Industrial Ozone Generator

Designed to eliminate difficult odors,  kill phorid flies, and kill pathogens.

$950.00

Ozone Generator, PA2500

Category

Description

PA 2500 Industrial Ozone Generator

MANUAL

FEATURES AND SPECIFICATIONS

  • An easily programmed timer
  • 2,500 milligrams of Ozone per hour (measured with free air not pure O2 input)
  • Beige Hammertone scratch resistant aluminum cabinet
  • Four low maintenance parallel plate generators powered by two 5000-volt heavy duty transformers
  • Size: 14” long, 15” wide, 5.5” high. (36cm long x 38cm wide x 14cm high)
  • Weight: 22 lbs (10 kg)
  • Twin fans: with a combined output of 210 CFM. (6.0 m³/min)
  • Power Requirement: 120 volt/75 watt/60 hertz
  • Warranty: 2-year warranty

 

OZONE LEVEL CONTROL

  1. Review the FORMULA below and then:
  2. Set OZONE to desired setting
  3. Set TIMER to the desired setting
  4. Plug the unit into any convenient wall socket
  5. Switch the power to ON
  6. Monitor odor level and adjust output as required to control

 

The following formula and chart is suggested as a general guideline only. Use of the formula and chart will enable the user to determine the approximate milligrams per hour (MG/HR) of ozone required to odor situations. Ozone output will vary substantially with changes in temperature and humidity.  AREA x ODOR FACTOR = MG/HR required PA2500 MG/HR (Milligrams per hour in dry air)

 

OZONE OUTPUT AT SETTING

500     625     833     1042     1250     1485     1667     1875     2083     2292    2500

LO         1           2           3            4             5           6           7             8             9          HI

CUBIC METERS

  1. Measure the Cubic Meters (L x W x H) of the AREA being treated
  2. Estimate the ODOR FACTOR as follows:
  • • Light Odor Factor = 0.18 Medium Odor Factor = 0.65 Strong Odor Factor = 1.29
  1. Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below
  2. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required.
CUBIC FEET

1. Measure the Cubic Footage (L x W x H) of the AREA being treated

2. Estimate the ODOR FACTOR as follows:

• • • Light Odor Factor = 0.005 Medium Odor Factor = 0.018 Strong Odor Factor = 0.036

3. Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below

4. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required.

 

Example:

1,000 cubic meter room x 1.29 Strong

Odor Factor = 1290 MG/HR. Set OZONE at 4 (1250 MG/HR) and adjust as required.

Example:

35,000 cubic foot room x 0.036 Strong

Odor Factor = 1260 MG/HR. Set OZONE at 4 (1250 MG/HR) and adjust as required.

 

Reviews

There are no reviews yet.

Be the first to review “Ozone Generator, PA2500”

Your email address will not be published. Required fields are marked *