Ozone Generator, PA1200

PA 1200  Industrial Ozone Generators

Eliminates odors and kills pathogens

$535.00

Ozone Generator, PA1200

Category

Description

PA 1200 Industrial Ozone Generator

MANUAL

FEATURES AND SPECIFICATIONS

  • An easily programmed timer
  • 1,200 milligrams of Ozone per hour (measured with free air not pure O2 input)
  • Beige Hammertone scratch resistant aluminum cabinet
  • Two low maintenance parallel plate generators powered by 5000-volt heavy duty transformers
  • Size: 14” long, 9” wide, 5.5” high. (36cm long x 23cm wide x 14cm high)
  • Weight: 10.5 lbs (5.4 kg)
  • Fan: 105 CFM. (3.0 m³/min)
  • Power Requirement: 120 volt/57 watt/60 hertz
  • Warranty: 2-year warranty

 

OZONE LEVEL CONTROL

  1. Review the FORMULA below and then:
  2. Set OZONE to desired setting
  3. Set TIMER to the desired setting
  4. Plug the unit into any convenient wall socket
  5. Switch the power to ON
  6. Monitor odor level and adjust output as required to control

 

The following formula and chart is suggested as a general guideline only. Use of the formula and chart will enable the user to determine the approximate milligrams per hour (MG/HR) of ozone required to odor situations. Ozone output will vary substantially with changes in temperature and humidity.  AREA x ODOR FACTOR = MG/HR required PA1200 MG/HR (Milligrams per hour in dry air)

 

OZONE OUTPUT AT SETTING

340     431     522      613      704      795     886     977     1068     1159    1200

LO         1           2           3          4           5          6          7           8            9          HI

CUBIC METERS

  1. Measure the Cubic Meters (L x W x H) of the AREA being treated
  2. Estimate the ODOR FACTOR as follows:  Light Odor Factor = 0.18 Medium Odor Factor = 0.65 Strong Odor Factor = 1.29
  3. Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below
  4. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required.
CUBIC FEET

  1.  Measure the Cubic Footage (L x W x H) of the AREA being treated
  2. Estimate the ODOR FACTOR as follows:  Light Odor Factor = 0.005 Medium Odor Factor = 0.018 Strong Odor Factor = 0.036
  3. 3. Multiply the AREA by the ODOR FACTOR to determine the MG/HR on the chart below
  4. Set OZONE on the machine to the setting nearest the required MG/HR and adjust as required.

 

Example:

500 cubic meter room x 1.29 Strong Odor Factor = 709 MG/HR.  Set OZONE at 4 (704 MG/HR) and adjust as required.

Example:

20,000 cubic foot room x 0.036 Strong Odor Factor = 720 MG/HR. Set OZONE at 4 (704 MG/HR) and adjust as required.

Reviews

There are no reviews yet.

Be the first to review “Ozone Generator, PA1200”

Your email address will not be published. Required fields are marked *